TheSurgeX SX1115RT Surge Eliminator & Power Conditionerhas remote control capabilities for use in AC power distribution systems and can be interfaced with a sequential controller such as the SurgeX SEQ. Switched receptacles can be controlled with an applie
TheSurgeX SX1115RT Surge Eliminator & Power Conditionerhas remote control capabilities for use in AC power distribution systems and can be interfaced with a sequential controller such as the SurgeX SEQ. Switched receptacles can be controlled with an applied voltage (5 to 30 VDC) or contact closure switch connected to the Phoenix connector on the back panel. The connector can also be used to cascade multiple units or provide status to a central controller.
The SX1115RT provides surge protection and power conditioning for audio, video, broadcast, and computer equipment. The units are 15A load-capable and have 8 industrial grade grounded AC receptacles (6 switched, 2 always on) plus a front-panel courtesy receptacle.
The unit features both common mode and normal mode impedance-tolerant EMI/RFI filtering, SurgeX ICE (Inrush Current Elimination), and COUVS (Catastrophic Over/Undervoltage Shutdown) for a complete power conditioning solution.
The SurgeX Advanced Series Mode technology is completely non-sacrificial. The zero let-through technology provides the most reliable protection available. It stops all surges up to 6000V (unlimited surge current) without producing harmful side effects such as ground contamination or common-mode disturbances.
Features
Specifications
Load Rating | 15 A @ 120 V |
Power Requirement | 15 W @ no load |
Certifications & Approvals | UL 1449 Adjunct Classification Test Results: 1,000 surges, 6,000 V, 3,000 A, B3 pulse Measured Suppressed Voltage: 170 V, no failures Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818) EMI/RFI Filter, Normal Mode (50 load): 40 dB at 100 kHz, 50 dB at 300 kHz, 50 dB at 3 MHz, 50 dB at 30 MHz EMI/RFI Filter, Common Mode (50 load): 18 dB at 300 kHz, 30 dB at 1 MHz, 50 dB at 5 MHz, 50 dB at 20 MHz |
Safety | Surge Let-Through Voltage (6,000 V surge): 0 V Maximum Applied Surge Voltage: 6,000 V Maximum Applied Surge Current: Unlimited, due to current limiting Maximum Applied Surge Energy: Unlimited, due to current limiting Endurance (C62.41-1991 Category B3 pulses): 1 kV > 500,000, 3 kV > 10,000, 6 kV > 1,000 Undervoltage Shutdown: 90 V (resume at 100 V) Overvoltage Shutdown: 145 V (resume at 135 V) Maximum Load Inrush Current During Power-up: 1,000 Joules |
Temperature Range | 41 to 95F (5 to 35C) |
Relay Contact Rating | Auxillary: 30 V @ 1 A |
LED Output | 12 VDC, maximum 20 mA (resistor required) |
Humidity Range | 5 to 95% R.H., non-condensing |
Packaging Info
Package Weight | 14.76 lb |
Box Dimensions (LxWxH) | 21.9 x 14.7 x 6.8″ |
Reviews
There are no reviews yet.