The 1U, 120V/20AProgrammable Sequencer Surge EliminatorfromSurgeXallows sequencing of various types of electronic equipment that need to be powered up or down in order, rather than simultaneously. In AV systems, sequencing is often necessary for controllin
The 1U, 120V/20AProgrammable Sequencer Surge EliminatorfromSurgeXallows sequencing of various types of electronic equipment that need to be powered up or down in order, rather than simultaneously. In AV systems, sequencing is often necessary for controlling the distribution of power to avoid equipment damage. This sequencer provides the sequencing parameters, conditioning, shutdown thresholds, and surge protection needed to safeguard audio, video, broadcast, and computer equipment. This unit has robust management features and is extremely easy to install, program, and use. It includes 2 always-on receptacles and 4 programmable banks. The SEQ features one virtual bank for controlling remote units, allowing for infinitely expanding distribution schemes. The SEQ also includes an LCD screen on the front panel that provides unit status, AC line voltage, and is also used in programming the unit. Settings are saved in nonvolatile memory. The SEQ can control other SurgeX products, or several SEQs can be interconnected to operate together. With many powerful features, the SEQ is extremely easy to install, program and use.
This surge elliminator is engineered with Advanced Series Mode surge elimination technology to provide top-of-the-line protection. Completely non-sacrificial and never needing reset, they provide reliable protection and eliminate surge energy up to 6,000V without producing harmful side effects such as ground contamination or common-mode disturbances. The SEQ Sequencer also features both common mode and normal mode impedance tolerant EMI/RFI filtering, SurgeX ICE (Inrush current elimination), and CouVS (Catastrophic over/under Voltage shutdown) for a complete power conditioning solution.
Specifications
Load Rating | 20 A @ 120 V |
Certifications & Approvals | UL 1449 Adjunct Classification Test Results: 1,000 surges, 6,000 V, 3,000 A, B3 pulse Measured suppressed voltage: 170 V, no failures Federal Guidelines: Grade A, Class 1, Mode 1 (CID A-A-55818) EMI/RFI Filter, Normal Mode (50 load): > 30 dB at 100 KHz to 50 MHz EMI/RFI Filter, Common Mode (50 load): > 20 dB (1 to 50 MHz) Under-Voltage Auto Shutdown: Adjustable from 90 to 110 V Over-Voltage Auto Shutdown: Adjustable from 130 to 150 V |
Safety | Surge Let-Through Voltage (6,000 V surge): 0 V Maximum Applied Surge Voltage: 6,000 V Maximum Applied Surge Current: Unlimited, due to current limiting Maximum Applied Surge Energy: Unlimited, due to current limiting Endurance (C62.41-1991 Category B3 pulses): 1 kV > 500,000, 3 kV > 10,000, 6 kV > 1,000 Maximum Load Inrush Energy: 1,400 Joules total during power-up |
Control Input | Momentary Switch, Latching Switch, Contact Closure, or 5 to 30 VDC |
Current | Input Control Current: 3 mA Contact Closure Maximum Resistance: 40 mA |
Output | DC: 12 VDC, 40 mA maximum load Auxiliary Relay Contact Rating: 30 VDC at 1 A |
Resistance | 12 VDC Output Maximum Current: 100 |
Delay | 1 to 40 seconds in 1 second increments |
Temperature Range | 41 to 95F (5 to 35C) |
Humidity Range | 5 to 95% R.H., non-condensing |
Listings | UL 1449 3rd Edition (Pending), UL 1283 5th Edition (Pending), CSA C22.2 No.8-M1986 (R2008) (Pending) |
Dimensions | 1.75 x 19.0 x 12.25″ (4.40 x 48.30 x 31.00 cm) |
Weight | 13.0 lb (5.9 kg) |
Reviews
There are no reviews yet.