Digi-Loop is definitely state-of-the-art the first of its kind to maximize modern amplifier technology. Its network-control capability provides seamless, remote system set-up, operation and monitoring via laptop or tablet. DSP audio processing offers flexible, powerful software control of mixing, equalization, compression and more. Powerful Class D, pulse-width amplifiers maximize efficiency.
The Digi-Loops amplifier design offers either single or dual 9.5 A rms loop outputs for perimeter loop(s), single array(s), dual loop, or phased-array configuration. A 70-100 V input provides connection to a distributed speaker/paging system, ensuring announcements are heard by loop users.
Features
- Network control – allows control and calibration of unit remotely with application software
- High continuous current 9.5 Arms (13.4 Apk) per output continuous
- LCD Screen with VU metering, easy one-button menu control
- DSP Audio Processing
- Dante Input (D models)
- USB for firmware updates
- Input mixing, parametric equalization, compression, metal compensation, high and low-pass filters, AGC and audio delay
- Power-save mode
- Adjustable output delay for multiple amps in large venues
- Fault warning and active protection against shorted or open circuits and overheating
- Loop fault relay output
- XLR and 3-position terminal block input configurable as microphone input or line-input, balanced or unbalanced.
- Standard 1 RU, 19 rackmount
- Magnetic signal couples directly to devices equipped with telecoils (T-coils) such as hearing aids, cochlear implants, or optional loop receivers.
- DL207 suitable for phased-array or dual-loop systems; DL107 suitable for perimeter loop or single array.
- Phased-array mode automatically produces 90 phase shift in slave loop output
- Meets IEC 60118-4 system performance requirements when integrated into a correctly designed and installed system.
- Meets IEC Specification 60118-4 (when designed and commissioned properly)
- Tested to IEC Specifications 62489-1 Benchmark Standards
Specifications
- Fan cooling: Variable Speed, Temperature Controlled
- Ethernet:(1x) RJ-45; 10-100 MBps.
- USB: (1x) standard-B. USB 1.1, 2.0 or 3.0 supported.
- Coverage area*
- 15,000 sq. ft. (1,393 sq. m.) (Perimeter Loop, 3:1 aspect ratio)
- 9,000sq. ft. (836 sq. m.) (Perimeter Loop, 1:1 aspect ratio)
- Dante input: On D models only. (1x) RJ-45;100 Mbps. Minimum latency: 2 ms. Audio sample rates supported: 44.1, 48 kHz. Resolution: 24 bits.
- Line inputs:(1x) 3-position terminal block, 10 k input impedance. Configurable/accepts -10 dBV, -4 dBu, +4 dBu, +8 dBu, balanced or unbalanced. Level adjustable 0 to -96 dB.
- Mic/Line inputs: (1x) XLR 3-pin jack. Input impedance: 1.5 k Mic, 10 k Line. Configurable/Accepts: Mic, Line -10 dBV, Line +4 dBu, or Line +8 dBu, balanced or unbalanced. Phantom supply (24V).
- 70-100 V input: (1x) 2-position terminal block; high/speaker-level input (accepts 25 V, 70 V or 100 V) from distributed audio/paging systems.
- Line outputs: (1x) 3-position terminal block; loop-through of Mic/Line Input 1 & Line Input 2, +4 dBu, Balanced or Unbalanced. The line outputs mirror the audio of the loop output.
- Loop output(s): (1x) 2-position terminal block per output
- Audio output delay: Adjustable from 0 to 165 msec
- Headphone output: (1x) 1/4 stereo headphone jack, on front of unit. Monitored input or output selectable in menu.
- Loop fault relay: (1x) 3-position terminal block providing NC, NO and Common. Contact rating: 2.0 A @ 30 VDC.
- Front controls: Front LCD display menu access/adjustment via control button/dial.
- Adjustable settings: Input mixing, parametric equalization, compression, metal loss compensation, high and low-pass filters, AGC and audio delay, output levels. See User Manual for adjustment range(s).
- Internal calibration tools: Test tone generator with pink noise, loop current adjustment/matching. See User Manual for details.
- Other features: Save/load configuration, loop test, priority input selection with adjustable threshold, loop fault relay, open/short and thermal protection. See User Manual for details.
- Network control & firmware: Function control and calibration by DigiLoop PC App via ethernet (RJ-45). PC App requires Windows 7 or higher.Firmware updates through USB only.